PHYSICAL PROPERTIES
|
TEST METHODS
|
AVERAGE RESULTS
|
| Thickness |
ASTM D 1000
-Substrate
-Adhesive
-Total |
0.0025 inch (0.063 mm)
0.0017 inch (0.043 mm)
0.0042 inch (0.106 mm)
|
Adhesion to:
-Stainless Steel |
ASTM D 1000
20 minute dwell
24 hour dwell |
40 oz/in (44 N/100 mm)
55 oz/in (61 N/100 mm)
|
| Tack |
ASTM D2979
Polyken™ Probe Tack
1 second dwell |
29 oz (800 g)
|
| Drop Shear |
PSTC-7 (except use 1/2" x 1" sample) |
>100 hours
|
| Dielectric Strength |
ASTM D 1000 |
11,000 Volts Total
|
| Adhesive Surface Resistivity |
EOS/ESD S11.11 |
1 x 108 ohms/sq
|
| Liner Surface Resistivity |
EOS/ESD S11.11
- Release side
- Backside |
1.7 x 1010 ohms/sq
2.5 x 109 ohms/sq
|
| Static Decay - Adhesive |
EIA-541 to 1% of initial charge |
0.01 seconds
|
| Static Decay - Liner |
EIA-541 to 1% of initial charge
- Release side |
0.3 seconds
|
| Voltage (Label removed from liner, adhesive tested) |
Value is obtained by removing a 1.5" x 0.25" label from liner and immediately holding label to a static sensing device calibrated in volts. |
4 volts
|
| Voltage (Label removed from liner, liner tested) |
Value is obtained by removing a label from liner and immediately holding label to a static sensing device calibrated in volts. |
2.7 volts
|
Samples printed with Series R6000 and Series R6000HF thermal transfer ribbons. Labels printed with 3:1 ratio bar codes with 6 mil X dimension bars. Samples laminated to aluminum panels. All samples allowed to dwell 24 hours prior to testing. Samples exposed to the indicated environments.
|
PERFORMANCE PROPERTIES
|
TEST METHOD
|
TYPICAL RESULTS
|
|
Short Term High Service Temperature
|
80 seconds at 572°F (300°C)
|
No visible effect to label at 572°F (300°C), label discolors slightly at 626°F (330°C), but still functional, at 662°F (350°C) label still functional but moderately discolored and adhesive discolored at label edge; print is still legible.
|
|
5 minutes at 500°F (250°C)
|
No visible effect to label at 500°F (260°C), label discolors slightly at 518°F (270°C), at 572°F (300°C) label moderately discolors and adhesive discolors at label edge. Label remains functional.
|
|
2 hours at 338°F (170°C)
|
No visible effect to label at 338°F (170°C), label discolors slightly at 374°F (190°C), moderately at 428°F (220°C) and severely at 500°F (260°C). Label remains functional.
|
|
Long Term High Service Temperature
|
1000 hours at 212°F (100°C)
|
No visible effect to label at 212°F (100°C), label discolors slightly at 248°F (120°C), moderately at 293°F (145°C). Label remains functional.
|
|
Low Service Temperature
|
1000 hours at -94°F (-70°C)
|
No visible effect
|
|
Humidity Resistance
|
1000 hours at 100°F (37°C)/95% RH
|
No visible effect
|
|
UV Light Resistance
|
1000 hours in UV SunlighterTM 100
|
Topcoat turns light yellow, label remains functional
|
|
Weatherability
|
ASTM G155, Cycle 1
1000 hours in Xenon Arc
Weatherometer
|
Slight discoloration
|
|
Salt Fog Resistance
|
ASTM B117
30 days in 5% salt fog solution chamber
|
No visible effect
|
|
Abrasion Resistance
|
Taber Abraser, CS-10 grinding wheels, 500 g/arm (Fed. Std. 191A, Method 5306)
|
Print legible to 100 cycles
|
|
Vapor Phase Resistance
|
Label adhered to epoxy PC board and exposed to:
2 minutes in FluorinertTM FC-5312 vapor phase at 420°F (216°C)
|
R6000 - No visible effect without rub, moderate to total print smear with rub. R6000HF - Not Tested
|
*B-477 is not recommended for outdoor use.
|
PERFORMANCE PROPERTY
|
CHEMICAL RESISTANCE
|
Samples printed with Series R6000 and Series R6000HF thermal transfer ribbon. Labels printed with 3:1 ratio barcodes with 6 mil X dimension bars. Samples exposed to indicated environments.
|
TEST ENVIRONMENT
|
CHEMICAL RESISTANCE
|
|
|
LABEL EFFECT
|
R6000
|
R6000HF
|
|
Kyzen Corp. Aquanox SSA™ 30% aqueous, 40-45°C - 10 minutes
|
No visible effect
|
1
|
1
|
|
Isopropyl Alcohol 99%, 82°C –
10 minutes
|
No visible effect
|
1-2
|
1-2
|
|
BIOACT® EC-7R™ Terpene Cleaner,
40-45°C - 10 minutes
|
No visible effect
|
1-2
|
1-2
|
|
Deionized Water, 100°C - 10 minutes
|
No visible effect
|
1
|
1
|
|
Alpha Metals Inc. 2110 Saponifier 6% aqueous, 65-70°C - 10 minutes
|
No visible effect
|
2
|
2-3
|
|
Lenuim ES – Vapor phase – 10 minutes
|
No visible effect
|
4
|
4
|
Rating scale:
1 – no visible effect
2 – slight smear or print removal, detectable but minimal smear
3 – moderate smear or print removal (print still legible)
4 – severe smear or print removal (print illegible or just barely legible)
5 – complete print removal
|
PERFORMANCE PROPERTY
|
TEST METHOD
|
|
Chemical Resistance
|
MIL-STD-202G, Notice 12, Method 215K
|
Samples printed with Series R6000 and Series R6000HF thermal transfer ribbons. Labels printed with alphanumerics and 3:1 ratio barcodes with 6 mil X dimension bars. Samples subjected to 3 cycles of 3 minute immersions immediately followed by a toothbrush rub after each immersion.
|
TEST FLUID
|
TYPICAL RESULTS
|
Solvent A
1 part IPA, 3 parts Mineral Spirits |
No visible effect
|
Solvent B
1,1,1-Trichloroethane |
Solvent deleted per Notice 12
|
Solvent C
Terpene Defluxer |
No visible effect
|
Solvent D
Saponifier at 70°C |
No visible effect
|
Product testing, customer feedback, and history of similar products, support a customer performance expectation of at least two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH . We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the risk of using such product. We encourage customers to develop functional testing protocols that will qualify a product's fitness for use in their actual applications.