Use:
B-529 is designed for printing indoor labels.
Adhesive Type:
Pressure sensitive acrylic
Substrate Type:
Polypropylene film
Standard Material Colors:
White
Standard Legend Color:
Black, red, blue, green, yellow and magenta
Thickness (PSTC-33):
0.0035 in. (0.09 mm)
Gloss (ASTM D523):
60° - 80 Gardner Units
Adhesive Properties:
Adhesion to Steel (PSTC-1)
15 Minute Dwell (Avg.) - 45 oz/in. (49 N/100mm)
Ultimate Dwell (72 Hrs.) (Avg.) - 83 oz/in. (91 N/100mm)
Tack (ASTM D 2979) (Avg.) - 1483 g. (14.5 N)
Abrasion Resistance (Method 5306 of U.S. Federal Test Method Std. No. 191A):
CS-10 wheels, 250 g wts.
The printed legend withstands up to 125 cycles.
Minimum Application Temperature:
50°F (10°C)
Service Temperature:
-40°F to 212°F (-40°C to 100°C)
Average Outdoor Durability:
Not Recommended
Chemical Resistance:
|
REAGENT
|
7 DAY IMMERSION
|
DIP TEST
|
RUB TEST
|
| 30% Sulfuric Acid |
NE
|
NE
|
NE
|
| 10% Sulfuric Acid |
NE
|
NE
|
NE
|
| 30% Hydrochloric Acid |
NE
|
NE
|
NE
|
| 10% Hydrochloric Acid |
NE
|
NE
|
NE
|
| Glacial Acetic Acid |
F
|
F
|
F
|
| 5% Acetic Acid |
NE
|
NE
|
NE
|
| 50% Sodium Hydroxide |
NE
|
NE
|
NE
|
| 10% Sodium Hydroxide |
F
|
NE
|
NE
|
| 10% Ammonia |
F
|
NE
|
NE
|
| 5% Sodium Hypochlorite |
F
|
NE
|
NE
|
| Methyl Ethyl Ketone |
F
|
F
|
F
|
| Acetone |
F
|
F
|
F
|
| Toluene |
F
|
F
|
F
|
| 1,1,1 - Trichloroethane |
F
|
F
|
F
|
| Methanol |
F
|
F
|
F
|
| Isopropyl Alcohol |
F
|
F
|
F
|
| Heptane |
F
|
NE
|
NE
|
| Mineral Spirits |
F
|
NE
|
NE
|
| T urpentine |
F
|
NE
|
F
|
| Kerosene |
F
|
NE
|
NE
|
| Diesel Fuel |
F
|
NE
|
NE
|
| Gasoline |
F
|
NE
|
F
|
| ASTM #3 Oil |
NE
|
NE
|
NE
|
| SAE 20 Oil |
NE
|
NE
|
NE
|
| 10% Sodium Chloride |
NE
|
NE
|
NE
|
| Alconox® |
F
|
NE
|
NE
|
| Water |
NE
|
NE
|
NE
|
NE = No Effect
F = Failed (affected Sample)
7 Day Immersion: Immersed in reagent for 7 days.
Dip Test: Five 10 minute dips in reagent with 30 minute recovery.
Rub Test: Rubbed sample for 1 minute with swab soaked in reagent.
Product testing, customer feedback, and history of similar products, support a customer performance expectation of at least two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH . We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the risk of using such product. We encourage customers to develop functional testing protocols that will qualify a product's fitness for use in their actual applications.