PHYSICAL PROPERTIES
|
TEST METHODS
|
AVERAGE RESULTS
|
| Thickness |
ASTM D 1000
-Total |
0.0075 inch (0.191 mm)
|
Adhesion to:
-Stainless Steel
-Textured ABS
-Polypropylene |
ASTM D 1000
20 minute dwell
24 hour dwell
20 minute dwell
24 hour dwell
20 minute dwell
24 hour dwell |
38 oz/in (42 N/100 mm)
41oz/in (45 N/100 mm)
29 oz/in (36 N/100 mm)
30 oz/in (38 N/100 mm)
33 oz/in (32 N/100 mm)
35 oz/in (33 N/100 mm)
|
| Tack |
ASTM D 2979
Polyken™ Probe Tack
1 second dwell |
16.4 oz (465 g)
|
| Tensile Strength and Elongation |
ASTM D 1000
-Machine Direction
-Cross Direction |
20 lbs/in (350 N/100 mm), 6%
10 lbs/in (175 N/100 mm), 8%
|
| Application Temperature |
Lowest application temperature to stainless steel |
50°F (10°C)
|
B-542 samples tested for Performance Properties were applied to stainless steel and phenolic panels and allowed to dwell 24 hours at room temperature prior to testing.
|
PERFORMANCE PROPERTIES
|
TEST METHODS
|
TYPICAL RESULTS
|
| Short Term High Service Temperature |
2 hours at: 293°F (145°C) |
Very slight discoloration of tape. Removed cleanly from stainless steel and phenolic without adhesive residue. |
| Short Term Low Service Temperature |
2 hours at: -40°F (-40°C) |
No visible effect |
| Long Term High Service Temperature |
30 days at: 122°F (50°C) |
No visible effect to tape. Removed cleanly from stainless steel and phenolic without adhesive residue. Some adhesive residue at 30 day temperatures greater than 175°F (80°C ). |
| Long Term Low Service Temperature |
30 days at: -40°F (-40°C) |
No visible effect |
| Humidity Resistance |
30 days at 100°F (37°C), 95% R.H. |
No visible effect to tape. Removed cleanly from stainless steel and phenolic without adhesive residue. |
| UV Light Resistance |
30 days in UV Sunlighter™ 100 |
Tape discolored and embrittled, and is no longer removable. B-542 is not recommended for outdoor applications. |
Product testing, customer feedback, and history of similar products, support a customer performance expectation of at least two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH . We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the risk of using such product. We encourage customers to develop functional testing protocols that will qualify a product's fitness for use in their actual applications.