Use:
Brady B-575 is used for general labeling and marking indoors.
Substrate Type:
Brushed, metalized polyester film
Adhesive Type:
Permanent pressure sensitive acrylic
Standard Material Colors:
Brushed gold
Standard Legend Colors:
Black, White, Red, Blue, Green, Magenta, Yellow, Orange (Process colors not recommended)
Thickness (PSTC-33):
0.006 in. (0.15 mm)
Adhesive Properties:
Adhesion to Steel (PSTC-1)
15 Minute Dwell (Avg.)- 80 oz/in. (87.5 N/100mm)
Ultimate Dwell-72 Hrs.(Avg.) - 85 oz/in. (93 N/100mm)
Tack(ASTM D 2979)(Avg.)-1197g. (11.7 N)
Abrasion Resistance (Method 5306 of U.S. Federal Test Method Std. No. 191A):
CS-10 wheels, 250 g wts.
The printed legend withstands up to 150 cycles.
Minimum Application Temperature:
50°F (10°C)
Service Temperature:
-40°F to 293°F (-40°C to 145°C)
Average Outdoor Durability:
Not recommended for outdoor use.
Chemical Resistance:
|
REAGENT
|
DIP TEST
|
RUB TEST
|
| 30% Sulfuric Acid |
NE
|
NE
|
| 10% Sulfuric Acid |
NE
|
NE
|
| 30% Hydrochloric Acid |
NE
|
NE
|
| 10% Hydrochloric Acid |
NE
|
NE
|
| Glacial Acetic Acid |
F
|
F
|
| 5% Acetic Acid |
NE
|
NE
|
| 50% Sodium Hydroxide |
NE
|
NE
|
| 10% Sodium Hydroxide |
NE
</ td> |
NE
|
| 10% Ammonia |
NE
|
NE
|
| 5% Sodium Hypochlorite |
NE
|
NE
|
| Methyl Ethyl Ketone |
F
|
F
|
| Acetone |
F
|
F
|
| Toluene |
NE
|
F
|
| 1,1,1-Trichloroethane |
F
|
F
|
| Methanol |
F
|
F
|
| Isopropyl Alcohol |
NE
|
NE
|
| Heptane |
NE
|
NE
|
| Mineral Spirits |
NE
|
NE
|
| Turpentine |
NE
|
NE
|
| Kerosene |
NE
|
NE
|
| Diesel Fuel |
NE
|
NE
|
| Gasoline |
F
|
NE
|
| ASTM #3 Oil |
NE
|
NE
|
| SAE 20 Oil |
NE
|
NE
|
| 10% Sodium Chloride |
NE
|
NE
|
| Alconox® |
< div align="center">NE |
NE
|
| Water |
NE
|
NE
|
NE = No Effect
F = Failed (affected Sample)
Dip Test: Five 10 minute dips in reagent with 30 minute recovery.
Rub Test: Rubbed sample for 1 minute with swab soaked in reagent.
Product testing, customer feedback, and history of similar products, support a customer performance expectation of at least two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80°F (27°C) and 60% RH . We are confident that our product will perform well beyond this time frame. However, it remains the responsibility of the user to assess the risk of using such product. We encourage customers to develop functional testing protocols that will qualify a product's fitness for use in their actual applications.